查了一下故障表,Pressure Switch坏的可能性很大, 先看看Vent的情况,堵没堵。启动后 Inducer Fan 转吗,然后 短路Pressure Switch看看怎么样?就能判断出是不是PressureSwitch的问题。

31 PRESSURE SWITCH DID NOT CLOSE OR REOPENED - If open longer than
five minutes, inducer shuts off for 15 minutes before retry. Check for:
- Excessive wind - Proper vent sizing - Defective inducer motor
- Low inducer voltage (115VAC) - Defective pressure switch
- Inadequate combustion air supply - Restricted vent
- Disconnected or obstructed pressure tubing
- Low inlet gas pressure (if LGPS used)
If it opens during blower on-delay period, blower will come on for the selected
blower off-delay.
查了一下故障表,Pressure Switch坏的可能性很大, 先看看Vent的情况,堵没堵。启动后 Inducer Fan 转吗,然后 短路Pressure Switch看看怎么样?就能判断出是不是PressureSwitch的问题。
Report

Replies, comments and Discussions:

  • 枫下家园 / 家用电器 / 暖氣爐轟隆隆的響聲和平時一樣,就是沒有暖風吹上來, 想請教是哪兒出了問題。 謝謝!
    • 读码。估计只有风扇转,但没火。自己观察有没有点火燃烧
      • 风扇放在 on上,工作有风吹出,可放在Auto 上, 等暖气炉工作时,没有风吹出来。
        • 相同的毛病,Carrier Furnace, 搜索了一圈说可能是fan& limit control switch坏了。正在联系经销商。
          • 现在高效的炉子,应该不用FAN Control Switch. 按照故障灯查一查是什么原因,再买件更换。
            • LED Code 31. 好像是pressure switch坏了。不知道好买不。
              • 查了一下故障表,Pressure Switch坏的可能性很大, 先看看Vent的情况,堵没堵。启动后 Inducer Fan 转吗,然后 短路Pressure Switch看看怎么样?就能判断出是不是PressureSwitch的问题。
                31 PRESSURE SWITCH DID NOT CLOSE OR REOPENED - If open longer than
                five minutes, inducer shuts off for 15 minutes before retry. Check for:
                - Excessive wind - Proper vent sizing - Defective inducer motor
                - Low inducer voltage (115VAC) - Defective pressure switch
                - Inadequate combustion air supply - Restricted vent
                - Disconnected or obstructed pressure tubing
                - Low inlet gas pressure (if LGPS used)
                If it opens during blower on-delay period, blower will come on for the selected
                blower off-delay.
                查了一下故障表,Pressure Switch坏的可能性很大, 先看看Vent的情况,堵没堵。启动后 Inducer Fan 转吗,然后 短路Pressure Switch看看怎么样?就能判断出是不是PressureSwitch的问题。
                • 专家,说的都是要点。是pressure switch坏了,现在修好了。
    • 请大家推荐个修暖气的师傅。先谢啦!
      • 同求!